mechanical indexers, indexers, drives, cam, dial tables, driven, mechanical, motion, control, cycly-index, cyclo, index

 
Application Requirements
  1. 1/2 revolution of output (180°)
  2. 45 R.P.M. input speed.
  3. 1/3 sec. dwell + 1/3 sec. index. Dwell-to-index ratio = 1.
  4. 2 transfers required per each revolution of input.
  5. Output torque required to select proper series size of unit.
Select model 90-1/2 to fulfill the dwell-to-index ratio, the 2 indexes per cycle of input rotation.
 
Kinematic Properties of Model 90-1/2[See Basic Motion Indexing Chart]
A=Angular acceleration factor = 8.20 rad./sec.2
Q=Input torque factor = 11.91
Compute Inertia of System
Compute Torque
Select 2800 Series Rated at 840 in.-lbs. [See Basic Motion Indexing Chart]
Select 2820A-90-1/2 Indexer [For standard shaft configuration]

Home Products Services Engineering Company
Ph: 417-358-6136   1129 W. Fairview Ave.
Fax: 417-358-8629   Carthage, MO 64836
Email Cyclo-Index