mechanical indexers, indexers, drives, cam, dial tables, driven, mechanical, motion, control, cycly-index, cyclo, index



Application Requirements
  1. 1/4 revolution of output (90°)
  2. 100 R.P.M. input speed.
  3. 0.45 sec. dwell + 0.15 sec. index. Dwell-to-index ratio = 3.
  4. 1 transfer required per each revolution of input.
  5. Output torque required to select proper series size of unit.
Select model 90-1/4 to fulfill the dwell-to-index ratio.
 
Kinematic Properties of Model 90-1/4[See Basic Motion Indexing Chart]
A=Angular acceleration factor = 3.41 rad./sec.2
Q=Input torque factor = 2.57

Compute Inertia of System
Compute Torque
Select 2400 Series Rated at 990 in.-lbs. [See Basic Motion Indexing Chart]
Select 2410A-90-1/4 Indexer [For standard shaft configuration]

Home Products Services Engineering Company
Ph: 417-358-6136   1129 W. Fairview Ave.
Fax: 417-358-8629   Carthage, MO 64836
Email Cyclo-Index